"Requested_prod_id","Requested_GTIN(EAN/UPC)","Requested_Icecat_id","ErrorMessage","Supplier","Prod_id","Icecat_id","GTIN(EAN/UPC)","Category","CatId","ProductFamily","ProductSeries","Model","Updated","Quality","On_Market","Product_Views","HighPic","HighPic Resolution","LowPic","Pic500x500","ThumbPic","Folder_PDF","Folder_Manual_PDF","ProductTitle","ShortDesc","ShortSummaryDescription","LongSummaryDescription","LongDesc","ProductGallery","ProductGallery Resolution","ProductGallery ExpirationDate","360","EU Energy Label","EU Product Fiche","PDF","Video/mp4","Other Multimedia","ProductMultimediaObject ExpirationDate","ReasonsToBuy","Spec 1","Spec 2","Spec 3","Spec 4","Spec 5","Spec 6","Spec 7","Spec 8","Spec 9","Spec 10","Spec 11","Spec 12","Spec 13","Spec 14","Spec 15","Spec 16","Spec 17","Spec 18","Spec 19","Spec 20","Spec 21","Spec 22","Spec 23","Spec 24","Spec 25","Spec 26","Spec 27","Spec 28","Spec 29","Spec 30","Spec 31","Spec 32","Spec 33","Spec 34","Spec 35","Spec 36","Spec 37","Spec 38","Spec 39","Spec 40","Spec 41","Spec 42","Spec 43","Spec 44","Spec 45","Spec 46","Spec 47","Spec 48","Spec 49","Spec 50","Spec 51","Spec 52","Spec 53","Spec 54","Spec 55","Spec 56","Spec 57","Spec 58","Spec 59","Spec 60" "","","77105295","","Tripp Lite","S3M100KXD","77105295","0037332239846|037332239846","Uninterruptible Power Supplies (UPSs)","817","","","S3M100KXD SmartOnline S3MX Series 3-Phase 380/400/415V 100kVA 90kW On-Line Double-Conversion UPS, Parallel for Capacity and Redundancy, Single & Dual AC Input","20221004145419","ICECAT","1","54868","https://images.icecat.biz/img/gallery/77105295_5220108940.jpg","1200x1200","https://images.icecat.biz/img/gallery_lows/77105295_5220108940.jpg","https://images.icecat.biz/img/gallery_mediums/77105295_5220108940.jpg","https://images.icecat.biz/img/gallery_thumbs/77105295_5220108940.jpg","http://objects.icecat.biz/objects/mmo_77105295_1640199824_9233_19592.pdf","","Tripp Lite S3M100KXD SmartOnline S3MX Series 3-Phase 380/400/415V 100kVA 90kW On-Line Double-Conversion UPS, Parallel for Capacity and Redundancy, Single & Dual AC Input","SmartOnline S3MX Series 3-Phase 380/400/415V 100kVA 90kW On-Line Double-Conversion UPS, Parallel for Capacity and Redundancy, Single & Dual AC Input","Tripp Lite S3M100KXD SmartOnline S3MX Series 3-Phase 380/400/415V 100kVA 90kW On-Line Double-Conversion UPS, Parallel for Capacity and Redundancy, Single & Dual AC Input, Double-conversion (Online), 100 kVA, 90000 W, Pure sine, 220 V, 415 V","Tripp Lite S3M100KXD SmartOnline S3MX Series 3-Phase 380/400/415V 100kVA 90kW On-Line Double-Conversion UPS, Parallel for Capacity and Redundancy, Single & Dual AC Input. UPS topology: Double-conversion (Online), Output power capacity: 100 kVA, Output power: 90000 W. Serial interface type: RS-232. Form factor: Tower, Product colour: Black, Housing material: Steel. Width: 566.9 mm, Depth: 944.9 mm, Height: 1015 mm. Cables included: RS-232","Battery Backup and VFI Operation Protect Critical Loads\nThe SmartOnline® S3M100KXD IGBT UPS supports the continuous availability of your most important loads through all power conditions, providing a compact backup power platform that’s easy to manage and inexpensive to operate. Sophisticated voltage and frequency independent (VFI) operation and advanced IGBT rectifier technology with DSP control deliver reliable output power quality. Providing up to 100kVA of clean, continuous power, this 3-phase UPS system is perfect for critical applications in IT, communications, corporate, commercial, retail, financial, security, transportation, emergency and edge infrastructure environments.\n\nBest-in-Class Footprint for Easy Integration into Your Network Application\nThis on-line double-conversion UPS system has a very small footprint of just 0.54 square meters. It requires less valuable space in your data center, and you can install the UPS system in spaces that would previously have required expensive retrofitting.\n\nEfficient Operation and Design Reduces Cost of Ownership\nThis UPS benefits from highly efficient transformer-free double-conversion technology that delivers operating cost savings. It achieves 94% efficiency in double-conversion mode and up to 98% in ECO mode, reducing your power and cooling costs. A low THDi (<3%) improves generator compatibility. A low THDv (≤2%) and active power factor correction improve output performance. The hardware and firmware platform design reduces the number of unique boards, improving mean time to repair (MTTR) and resulting in reduced downtime. Built-in static and maintenance bypass transfer UPS load to utility power during faults, overloads and maintenance, which also avoids costly system downtime.\n\nExternal Batteries Supply Reliable Backup with Expandable Runtime Options\nThe S3M100KXD uses external scalable battery cabinets, such as BP480V65 and BP480V100 (sold separately), to provide up to three hours of backup support in case of a power failure. Add the optional TEMPC100200 thermostat kit to enable temperature-compensated charging for optimized battery lifespan. The UPS system automatically restarts after a lengthy power outage.\n\nIntuitive Color Touchscreen Display Delivers Important Performance Information at a Glance\nThe large (25.4 cm/10 inches) front-panel color interface enables comprehensive local monitoring and control capability. It displays critical operating conditions and diagnostic data, such as phase load levels, available runtime, alarm status, battery charge, and voltage and frequency values. Six LEDs indicate bypass, on-line, inverter, battery, load and alarm/fault modes.\n\nNetwork Management Card Offers Remote Monitoring and Control\nThe optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. Auto Probe allows a UPS with switched loads to automatically reboot devices if a network communication failure is detected. This preserves uptime and minimizes the time and expense associated with on-site support.\n\nParallel Capability Provides Additional Capacity\nConnect two S3M100KXD units in parallel using separate/shared battery cabinets for increased capacity or redundancy.\n\n2-Year Warranty Provides Peace of Mind\nThe S3M100KXD is backed by a 2-year warranty, ensuring reliability and performance.","https://images.icecat.biz/img/gallery/77105295_5220108940.jpg|https://images.icecat.biz/img/gallery/77105295_8157370500.jpg|https://images.icecat.biz/img/gallery/77105295_2744834205.jpg|https://images.icecat.biz/img/gallery/77105295_6566965483.jpg|https://images.icecat.biz/img/gallery/77105295_9550320352.jpg|https://images.icecat.biz/img/gallery/77105295_7726852153.jpg|https://images.icecat.biz/img/gallery/77105295_1316737093.jpg|https://images.icecat.biz/img/gallery/77105295_0068895524.jpg","1200x1200|1200x1200|1200x1200|1200x1200|1200x1200|1200x1200|1200x1200|1200x1200","|||||||","","","","","","","","","Features","UPS topology: Double-conversion (Online)","Output power capacity: 100 kVA","Output power: 90000 W","Waveform: Pure sine","Input operation voltage (min): 220 V","Input operation voltage (max): 415 V","Input frequency: 50/60 Hz","Output operation voltage (min): 220 V","Output operation voltage (max): 415 V","Output frequency: 50/60 Hz","Maximum current: 165 A","Number of input phases: 3","Number of output phases: 3","Input power factor: 0.99","Output power factor: 0.9","Crest factor: 3:1","Noise level: 70 dB","Country of origin: China","Ports & interfaces","Serial interface: Yes","Serial interface type: RS-232","Emergency Power Off (EPO) connector: Yes","Battery","Cold start: Yes","Design","Form factor: Tower","Product colour: Black","Housing material: Steel","Cooling type: Active","Built-in fan: Yes","Display type: LCD","LED indicators: Yes","Certification: CE","Operational conditions","Operating temperature (T-T): 0 - 40 °C","Storage temperature (T-T): -15 - 60 °C","Operating relative humidity (H-H): 5 - 95%","Storage relative humidity (H-H): 5 - 95%","Operating altitude: 0 - 1000 m","Technical details","Sustainability certificates: RoHS","Weight & dimensions","Width: 566.9 mm","Depth: 944.9 mm","Height: 1015 mm","Weight: 197 kg","Package width: 705.1 mm","Package depth: 1125 mm","Package height: 1180.1 mm","Package weight: 223.5 kg","Packaging data","Cables included: RS-232","Manual: Yes","Logistics data","Master (outer) case width: 705.1 mm","Master (outer) case length: 1125 mm","Master (outer) case height: 1180.1 mm","Master (outer) case gross weight: 223.5 kg","Products per master (outer) case: 1 pc(s)"